Single-crystal diffuse scattering measurements can now rapidly probe the three-dimensional structure of subtle defects in microporous framework materials. Diffuse scattering data from natural mordenite crystals are shown to exhibit a complex distribution of weak features which have been mapped out using a synchrotron X-ray source and a CCD detector. Comparison with computer-simulated diffuse scattering patterns yields a detailed three-dimensional columnar defect structure and reveals that roughly one third of the mordenite's columnar defects cooperate to form a block-mosaic pattern of {110} stacking faults.