Buy article online - an online subscription or single-article purchase is required to access this article.
Download citation
Download citation
link to html
D2AM is a french CRG beamline installed at the ESRF (European Synchrotron Radiation Facility) in Grenoble, with half of the time dedicated to biological macromolecule crystallography and half to materials science studies (diffraction, wide-angle and small-angle scattering). It is constructed at the front-end BM02 of the ESRF storage ring, using the X-ray beam from a 0.8 T bending magnet. D2AM entered into routine operation at the end of 1994, and is used either for single-wavelength or for multiwavelength anomalous diffraction studies. The beam is monochromated by an Si[111] two-crystal monochromator with a resolution of about 2 × 10−4. The first crystal is water cooled. The X-ray photon energy covers the range between 6.5 keV (λ ≃ 1.9 Å) and 17 keV (λ ≃ 0.7 Å), a domain of energy with many K or L absorption edges of heavy atoms of interest for biological macromolecules studies and in materials science. The X-ray beam is focused in the vertical plane by two long curved mirrors and in the horizontal plane by the second crystal of the monochromator which is given an adjustable sagittal curvature. A spot size of 0.3 × 0.1 mm (FWHM) is measured at the sample position. Both mirrors are cut out of a 6"-diameter 1.1 m-long Si single crystal, polished and coated with a 400 Å Pt thin film. The rugosity is better than 4 Å r.m.s. and the longitudinal slope error is better than 5 × 10−6 rad r.m.s. The first mirror is water cooled, the second is not. The beam intensity on the sample is about 1011 photon s−1 on a 0.3 × 0.3 mm focus area at 100 mA in the storage ring of the ESRF. The harmonic rejection ratio obtained with the two mirrors is better than 10−5 for λ/3. The combined optical system, mirror/monochromating-crystals/mirror, used on D2AM constitutes altogether a high-intensity point-focusing fixed-exit monochromator, which has the additional property that the energy resolution is not dependent on the beam divergence in use. Its stability and resolution are perfectly adapted to multiwavelength anomalous diffraction studies. The alignment of the mirrors and the monochromator is fully automated, taking 5 min, with the exception of the adjustment of the sagittal focusing. During multiwavelength diffraction experiments the wavelength is changed by a fast single monochromator rotation. Neither realignment of the mirrors nor readjustment of the beam focusing are necessary. The stability and reproducibility of the selected X-ray photon energy is better than 0.5 eV.

Subscribe to Journal of Synchrotron Radiation

The full text of this article is available to subscribers to the journal.

If you have already registered and are using a computer listed in your registration details, please email support@iucr.org for assistance.

Buy online

You may purchase this article in PDF and/or HTML formats. For purchasers in the European Community who do not have a VAT number, VAT will be added at the local rate. Payments to the IUCr are handled by WorldPay, who will accept payment by credit card in several currencies. To purchase the article, please complete the form below (fields marked * are required), and then click on `Continue'.
E-mail address* 
Repeat e-mail address* 
(for error checking) 

Format*   PDF (US $40)
   HTML (US $40)
   PDF+HTML (US $50)
In order for VAT to be shown for your country javascript needs to be enabled.

VAT number 
(non-UK EC countries only) 
Country* 
 

Terms and conditions of use
Contact us

Follow J. Synchrotron Rad.
Sign up for e-alerts
Follow J. Synchrotron Rad. on Twitter
Follow us on facebook
Sign up for RSS feeds