Buy article online - an online subscription or single-article purchase is required to access this article.
Download citation
Download citation
link to html
Lens-coupled indirect X-ray imaging detectors have the advantage of high resolution and the disadvantage of low detection efficiency. Using thicker single-crystalline films (SCFs) can improve the detection efficiency. However, the image quality will become worse due to the degradation of the point spread function (PSF) and modulation transfer function (MTF). This disadvantage can be improved by deconvolution with the PSF, which is unknown. In this article, a method was established to acquire the PSF based on a simulation of the imaging process for a lens-coupled indirect X-ray imaging detector. Because the structural parameters of commercial lenses cannot usually be obtained, the PSFs were calculated from lens performance parameters. PSFs were calculated using the conditions of 12 keV X-ray energy, 10× and 40× magnification objectives and 4.6 µm- and 20 µm-thick GGG:Tb scintillators. These were then used to deconvolve images of an Xradia resolution test pattern taken under the same conditions. The results show that after deconvolution the MTF had been clearly improved for both the 4.6 µm- and 20 µm-thick SCFs, indicating that the image has better quality than before deconvolution. Furthermore, a PSF deconvolution was performed on mouse brain tissue projection images, and the original and deconvolution projection images were used to perform computed-tomography reconstruction; the result proved that the method was effective for improving the image quality of low-contrast samples. Therefore, this method shows promise in allowing the use of thick SCFs to improve the detection efficiency while maintaining good image quality.

Subscribe to Journal of Synchrotron Radiation

The full text of this article is available to subscribers to the journal.

If you have already registered and are using a computer listed in your registration details, please email support@iucr.org for assistance.

Buy online

You may purchase this article in PDF and/or HTML formats. For purchasers in the European Community who do not have a VAT number, VAT will be added at the local rate. Payments to the IUCr are handled by WorldPay, who will accept payment by credit card in several currencies. To purchase the article, please complete the form below (fields marked * are required), and then click on `Continue'.
E-mail address* 
Repeat e-mail address* 
(for error checking) 

Format*   PDF (US $40)
   HTML (US $40)
   PDF+HTML (US $50)
In order for VAT to be shown for your country javascript needs to be enabled.

VAT number 
(non-UK EC countries only) 
Country* 
 

Terms and conditions of use
Contact us

Follow J. Synchrotron Rad.
Sign up for e-alerts
Follow J. Synchrotron Rad. on Twitter
Follow us on facebook
Sign up for RSS feeds