The neutron flux of the Compact Pulsed Hadron Source (CPHS) is about 2–3 orders of magnitude lower than that of large neutron sources, which means that the beam intensity should be improved to achieve good statistics. Multi-pinhole collimation can be used to obtain a lower Q with an acceptable beam intensity in a very small angle neutron scattering (VSANS) instrument and a higher beam intensity for a larger sample size in a small-angle neutron scattering (SANS) instrument. A new nine-pinhole structure is used in a SANS instrument at CPHS to achieve an acceptable range and resolution of Q and a higher beam intensity compared to single-pinhole collimation. The crosstalk issue associated with multi-pinhole collimation is addressed using an optimized algorithm to achieve a higher safety margin and a larger pinhole size with a higher beam intensity at the sample. Different collimator aperture structures are compared on the basis of their noise production. Experiments are performed to verify the theory of calculating reflection noise from the inner surface of the collimator's aperture and parasitic noise from the beveled collimator structure. From a simulated SANS experiment using cold neutrons in the SANS instrument, it is clarified that multi-pinhole collimators with an opening angle on the downstream side have better performance than those with an opening angle on the upstream side and straight-cut collimators. Compared with a single-pinhole collimation system, a nine-pinhole collimation system increases the intensity at the sample by approximately sevenfold when the sample size is increased by 20-fold for CPHS-SANS, and the signal-to-noise ratio is improved by exploiting a specific collimator aperture structure. Our goal is to install a multi-pinhole collimator based SANS instrument at CPHS in the future, and it is hoped that these results will serve to promote the utilization of multi-pinhole collimation systems at other facilities.

Subscribe to Journal of Applied Crystallography

The full text of this article is available to subscribers to the journal.

If you have already registered and are using a computer listed in your registration details, please email support@iucr.org for assistance.

Buy online

You may purchase this article in PDF and/or HTML formats. For purchasers in the European Community who do not have a VAT number, VAT will be added at the local rate. Payments to the IUCr are handled by WorldPay, who will accept payment by credit card in several currencies. To purchase the article, please complete the form below (fields marked * are required), and then click on `Continue'.
E-mail address* 
Repeat e-mail address* 
(for error checking) 

Format*   PDF (US $40)
   HTML (US $40)
   PDF+HTML (US $50)
In order for VAT to be shown for your country javascript needs to be enabled.

VAT number 
(non-UK EC countries only) 
Country* 
 

Terms and conditions of use
Contact us

Follow J. Appl. Cryst.
Sign up for e-alerts
Follow J. Appl. Cryst. on Twitter
Follow us on facebook
Sign up for RSS feeds