A commercially available small-angle X-ray scattering (SAXS) NanoSTAR instrument (Bruker AXS) with a liquid-metal-jet source (Excillum) has been optimized for solution scattering and installed at iNANO at Aarhus University. The instrument (named HyperSAXS) employs long high-quality parabolic Montel multilayer optics (Incoatec) and a novel compact scatterless pinhole slit with Ge edges, which was designed and built at Aarhus University. The combination of the powerful source and optimized geometry gives an integrated X-ray intensity close to 109 photons s−1 for a standard range of scattering vector moduli q = 0.0098–0.425 Å−1, where q = (4πsinθ)/λ and λ is the Ga Kα wavelength of 1.34 Å. The high intensity of the instrument makes it possible to measure dilute samples of, for example, protein or surfactant with concentrations of 1 mg ml−1 in a few minutes. A flow-through cell, built at Aarhus University, in combination with an automated sample handler has been installed on the instrument. The sample handler is based on the commercial Gilson GX-271 injection system (Biolab), which also allows samples to be stored under thermostatted conditions. The sample handler inserts and removes samples, and also cleans and dries the sample cell between measurements. The minimum volume of the flow-through capillary is about 20 µl. The high intensity additionally allows time-resolved measurements to be performed with a temporal resolution of seconds. For this purpose a stopped-flow apparatus, (SFM-3000, Bio-Logic) was connected to the flow-through cell by high-performance liquid chromatography tubing. This configuration was chosen as it allows vacuum around the sample cell and thus maintains a low background. The instrument can readily be converted into a low-q setup with a q range of 0.0049–0.34 Å−1 and an X-ray intensity of about 5 × 107 photons s−1.

Supporting information

pdf

Portable Document Format (PDF) file https://doi.org/10.1107/S1600576720016209/ge5083sup1.pdf
2D SAXS spectra; SUPERSAXS Upgrades; additional samples, methods and results; Guinier fit


Subscribe to Journal of Applied Crystallography

The full text of this article is available to subscribers to the journal.

If you have already registered and are using a computer listed in your registration details, please email support@iucr.org for assistance.

Buy online

You may purchase this article in PDF and/or HTML formats. For purchasers in the European Community who do not have a VAT number, VAT will be added at the local rate. Payments to the IUCr are handled by WorldPay, who will accept payment by credit card in several currencies. To purchase the article, please complete the form below (fields marked * are required), and then click on `Continue'.
E-mail address* 
Repeat e-mail address* 
(for error checking) 

Format*   PDF (US $40)
   HTML (US $40)
   PDF+HTML (US $50)
In order for VAT to be shown for your country javascript needs to be enabled.

VAT number 
(non-UK EC countries only) 
Country* 
 

Terms and conditions of use
Contact us

Follow J. Appl. Cryst.
Sign up for e-alerts
Follow J. Appl. Cryst. on Twitter
Follow us on facebook
Sign up for RSS feeds