Protein crystallography continues to be one of the most frequently used techniques to obtain structural information of biomacromolecules to atomic resolution. Since protein crystals of delicate target systems are often limited in size, one of the main goals in the design of modern beamlines is the construction of highly intense X-ray beams with small focal size to obtain high resolution diffraction images of microcrystals. However, this development has led to the situation, that the full intensity of the beam can destroy a protein crystal within fractions of a second. Therefore often only a small number of diffraction patterns can be obtained from one single crystal. Here we describe the adaptation of the serial crystallography approach, which has first been developed at X-ray Free-Electron Lasers (Chapman et al. 2011) to the usage of a microfocus synchrotron beamline, using a standard cryogenic loop for sample delivery. We proved this concept with in vivo grown cathepsinB microcrystals (TbCatB, Koopmann et al. 2012, Redecke et al. 2013) (average of 9 μm3), a medically and pharmaceutically relevant protein, involved in the life cycle of T. brucei. In these experiments it was possible to show that serial crystallography enables the utilization and outcome of the above described bottlenecks and features of modern 3rd generation synchrotron microfocus beamlines. Our strategy exploits the combination of a micron-sized X-ray beam, high precision diffractometry and shutterless data acquisition with a pixel-array detector. By combining the data of 80 TbCatB crystals, it was possible to assemble a dataset to 3.0 Å resolution. The data allow the refinement of a structural model that is consistent with that previously obtained using FEL radiation, providing mutual validation.

Download citation
Acta Cryst. (2014). A70, C570
Download citation

link to html
Peroxisomes are membrane-enclosed organelles in eukaryotic cells with important roles in lipid metabolism and the scavenging of reactive oxygen species. Peroxisomes are capable of carrying an unusually high load of proteins, which under appropriate nutrient conditions results in the in situ crystallization of peroxisomal proteins in several yeast species and vertebrate hepatocytes [1,2]. In the methylotrophic yeast H.polymorpha, the predominant peroxisomal protein alcohol/methanol oxidase (AO) oligomerizes into octameric assemblies with a molecular mass of 600 kDa that spontaneously form 200-500 nm crystallites within peroxisomes [1]. We exposed H.polymorpha cell suspensions containing peroxisome-confined AO crystallites to femtosecond X-ray pulses at the Coherent X-ray Imaging (CXI) experimental endstation at the Linac Coherent Light Source. Peak detection routines mining the resulting scattering profiles identified >5000 Bragg-sampled diffraction patterns, providing the proof of concept that background scattering from the cells does not deteriorate the signal-to-noise ratio to an extent precluding observation of diffraction from individual AO crystallites. Summation patterns assembled from the individual frames match low-resolution powder diffraction patterns from concentrated suspensions of purified peroxisomes collected at the P14 beamline at the PETRAIII synchrotron, confirming that the observed diffraction mainly results from Bragg scattering of peroxisomal crystallites. To the best of our knowledge our data are the first to report room temperature X-ray diffraction from functional protein crystals in their native cellular environment. Currently the maximum resolution achieved in the diffraction patterns is limited to 20-15 Å. Future work will need to address improved sample preparation protocols in order to assess whether diffraction to a resolution sufficient to permit structure solution can be obtained. Protein crystal formation in vivo has been observed under physiological or pathological conditions in a number of other systems [3]. We hope that our results will help to establish serial femtosecond X-ray diffraction (SFX) as a method for structural characterization of cellular structures with crystalline content and provide a proof of concept for using in situ crystallization of proteins as a means to generate nanocrystalline samples for SFX.

Download citation
Acta Cryst. (2014). A70, C694
Download citation

link to html
The European X-ray Free-Electron Laser (XFEL.EU) [1] will provide ultra-short, highly-intense, coherent x-ray pulses at an unprecedented repetition rate, transforming experiments in many scientific areas, including serial femtosecond crystallography (SFX). For the purpose of SFX experiments at the XFEL.EU, a dedicated endstation is being developed to be installed within the Single Particles, Clusters and Biomolecules (SPB) instrument [2]. The setup will refocus the beam spent by SPB into a second interaction region, thereby enabling two parallel experiments. In order to overcome various challenges in XFEL crystallography, and to optimize the output for SFX experiments at XFEL.EU, the Adaptive Gain Integrating Pixel Detector (AGIPD) [3] is currently under development and is to be implemented in the SPB instrument, including a 4 Megapixel version for the SFX apparatus. The AGIPD is a hybrid-pixel detector with pixels of 200 x 200 micron^2 each. The gain of each single pixel dynamically and independently adapts to the incoming signal. Thus, diffraction patterns of high dynamic range can be recorded, with the measured signal within a single data frame ranging from single photons and up to 1e+4 photons at 12 keV. Moreover, the AGIPD is designed to store over 350 data frames from successive pulses prior to digitization and read-out, thereby enabling operation at the European XFEL with its challenging repetition rate with 10 Hz pulse trains and a 4.5 MHz intra-train repetition rate. Furthermore, the incorporation of a veto system in AGIPD will allow one to potentially store only the frames that contain diffraction data from actual crystal hits, which ultimately increases the efficiency of the detector and DAQ systems dramatically. In the present work, we will review the design of the 4Mpix AGIPD for the SFX apparatus and discuss simulations and tests of its expected performance under the conditions foreseen for SFX experiments at the XFEL.EU.

Download citation
Acta Cryst. (2014). A70, C1748
Download citation

link to html
The Serial Femtosecond Crystallography (SFX) user's consortium apparatus is to be installed within the Single Particles, Clusters and Biomolecules (SPB) instrument of the European X-ray Free-Electron Laser facility (XFEL.EU) [1, 2]. The XFEL.EU will provide ultra-short, highly intense, coherent X-ray pulses at an unprecedented repetition rate. The experimental setup and methodological approaches of many scientific areas will be transformed, including structural biology that could potentially overcome common problems and bottlenecks encountered in crystallography, such as creating large crystals, dealing with radiation damage, or understanding sub-picosecond time-resolved phenomena. The key concept of the SFX method is based on the kinetic insertion of protein crystal samples in solution via a gas dynamic virtual nozzle jet and recording diffraction signals of individual, randomly oriented crystals passing through the XFEL beam, as first demonstrated by Chapman et al. [3]. The SFX-apparatus will refocus the beam spent by the SPB instrument into a second interaction region, in some cases enabling two parallel experiments. The planned photon energy range at the SPB instrument is from 3 to 16 keV. The Adaptive Gain Integrating Pixel Detector (AGIPD) is to be implemented in the SPB instrument, including a 4 Megapixel version for the SFX-apparatus. The AGIPD is designed to store over 350 data frames from successive pulses, and aims to collect more than 3,000 images per second. Together with the implementation of automated procedures for sample exchange and injection, high-throughput nanocrystallography experiments can be integrated at the SFX-apparatus. In this work, we review the overall design of the SFX-apparatus and discuss the main parameters and challenges