Download citation
Download citation
link to html
Utilization of an Si(331) beam conditioner together with an Si(111) double-crystal monochromator (DCM) enables the angular resolution of synchrotron X-ray topography to be increased by an order of magnitude compared with grazing-incidence topography or back-reflection topography conducted with the DCM alone. This improved technique with extremely small beam divergence is referred to as synchrotron X-ray plane-wave topography (SXPWT). This study demonstrates that the rocking curve width of 4H-SiC 0008 in PWT is only 2.5′′ and thus the lattice distortion at the scale of 1′′ will significantly affect the diffracted intensity. This work reports the ultra-high angular resolution in SXPWT which enables detailed probing of the lattice distortion outside the dislocation core in 4H-SiC, where the sign of the Burgers vector can be readily determined through comparison with ray-tracing simulations.

Supporting information

pdf

Portable Document Format (PDF) file https://doi.org/10.1107/S1600576722004046/te5093sup1.pdf
Supplemental diagram and calculations


Follow J. Appl. Cryst.
Sign up for e-alerts
Follow J. Appl. Cryst. on Twitter
Follow us on facebook
Sign up for RSS feeds