Download citation
Download citation
link to html
The title compound, C21H27N32+·2Cl·H2O, was synthesized from 1-benzyl­benzimidazole and 2-chloro­ethyl­piperidine hydro­chloride in dimethyl­formamide. In the cation, the benzimidazole ring is connected to the piperidine ring by an ethyl­ene group. The crystal structure is stabilized by O—H...Cl, N—H...Cl, C—H...O and C—H...Cl hydrogen-bonding inter­actions.

Supporting information

cif

Crystallographic Information File (CIF) https://doi.org/10.1107/S1600536805018337/su6204sup1.cif
Contains datablocks global, I

hkl

Structure factor file (CIF format) https://doi.org/10.1107/S1600536805018337/su6204Isup2.hkl
Contains datablock I

CCDC reference: 277797

Key indicators

  • Single-crystal X-ray study
  • T = 100 K
  • Mean [sigma](C-C) = 0.002 Å
  • R factor = 0.031
  • wR factor = 0.078
  • Data-to-parameter ratio = 17.4

checkCIF/PLATON results

No syntax errors found



Alert level C PLAT042_ALERT_1_C Calc. and Rep. MoietyFormula Strings Differ .... ? PLAT063_ALERT_3_C Crystal Probably too Large for Beam Size ....... 0.78 mm PLAT094_ALERT_2_C Ratio of Maximum / Minimum Residual Density .... 2.37 PLAT220_ALERT_2_C Large Non-Solvent C Ueq(max)/Ueq(min) ... 2.55 Ratio
0 ALERT level A = In general: serious problem 0 ALERT level B = Potentially serious problem 4 ALERT level C = Check and explain 0 ALERT level G = General alerts; check 1 ALERT type 1 CIF construction/syntax error, inconsistent or missing data 2 ALERT type 2 Indicator that the structure model may be wrong or deficient 1 ALERT type 3 Indicator that the structure quality may be low 0 ALERT type 4 Improvement, methodology, query or suggestion

Computing details top

Data collection: X-AREA (Stoe & Cie, 2002); cell refinement: X-AREA; data reduction: X-RED32 (Stoe & Cie, 2002); program(s) used to solve structure: SHELXS97 (Sheldrick, 1997); program(s) used to refine structure: SHELXL97 (Sheldrick, 1997); molecular graphics: ORTEP-3 for Windows (Farrugia, 1997); software used to prepare material for publication: WinGX (Farrugia, 1999).

1-Benzyl-3-[2-(1-piperidinio)ethyl]benzimidazolium dichloride monohydrate top
Crystal data top
C21H27N32+·2Cl·H2OF(000) = 872
Mr = 410.37Dx = 1.307 Mg m3
Monoclinic, P21/nMo Kα radiation, λ = 0.71073 Å
Hall symbol: -P 2ynCell parameters from 32468 reflections
a = 17.1422 (12) Åθ = 1.9–27.2°
b = 6.9643 (3) ŵ = 0.33 mm1
c = 18.2627 (13) ÅT = 100 K
β = 106.961 (5)°Plate, colourless
V = 2085.4 (2) Å30.78 × 0.49 × 0.18 mm
Z = 4
Data collection top
STOE IPDS-II
diffractometer
4535 independent reflections
Radiation source: sealed X-ray tube, 12 x 0.4 mm long-fine focus3875 reflections with I > 2σ(I)
Plane graphite monochromatorRint = 0.032
Detector resolution: 6.67 pixels mm-1θmax = 27.0°, θmin = 1.9°
ω scansh = 2121
Absorption correction: integration
(X-RED32; Stoe & Cie, 2002)
k = 88
Tmin = 0.784, Tmax = 0.943l = 2322
17638 measured reflections
Refinement top
Refinement on F2Primary atom site location: structure-invariant direct methods
Least-squares matrix: fullSecondary atom site location: difference Fourier map
R[F2 > 2σ(F2)] = 0.031Hydrogen site location: inferred from neighbouring sites
wR(F2) = 0.078H atoms treated by a mixture of independent and constrained refinement
S = 1.04 w = 1/[σ2(Fo2) + (0.0383P)2 + 0.7441P]
where P = (Fo2 + 2Fc2)/3
4535 reflections(Δ/σ)max = 0.001
260 parametersΔρmax = 0.43 e Å3
0 restraintsΔρmin = 0.18 e Å3
Special details top

Geometry. Bond distances, angles etc. have been calculated using the rounded fractional coordinates. All su's are estimated from the variances of the (full) variance-covariance matrix. The cell e.s.d.'s are taken into account in the estimation of distances, angles and torsion angles

Refinement. Refinement on F2 for ALL reflections except those flagged by the user for potential systematic errors. Weighted R-factors wR and all goodnesses of fit S are based on F2, conventional R-factors R are based on F, with F set to zero for negative F2. The observed criterion of F2 > σ(F2) is used only for calculating -R-factor-obs etc. and is not relevant to the choice of reflections for refinement. R-factors based on F2 are statistically about twice as large as those based on F, and R-factors based on ALL data will be even larger.

Fractional atomic coordinates and isotropic or equivalent isotropic displacement parameters (Å2) top
xyzUiso*/Ueq
N10.60526 (6)0.60317 (15)0.72070 (6)0.0180 (3)
N20.66715 (6)0.56138 (16)0.63281 (6)0.0178 (3)
N30.75431 (7)0.67803 (17)0.47262 (6)0.0210 (3)
C10.68830 (7)0.58849 (17)0.75901 (7)0.0175 (3)
C20.73043 (8)0.59974 (18)0.83650 (7)0.0189 (3)
C30.81446 (8)0.58467 (18)0.85470 (7)0.0205 (3)
C40.85466 (8)0.56040 (18)0.79863 (8)0.0208 (4)
C50.81249 (8)0.55002 (18)0.72131 (7)0.0196 (3)
C60.72793 (7)0.56407 (18)0.70307 (7)0.0176 (3)
C70.53983 (8)0.63691 (19)0.75667 (8)0.0203 (3)
C80.51394 (7)0.45483 (19)0.78796 (7)0.0192 (3)
C90.51512 (9)0.4445 (2)0.86433 (8)0.0267 (4)
C100.48832 (10)0.2787 (3)0.89199 (9)0.0349 (5)
C110.46069 (9)0.1245 (2)0.84372 (10)0.0329 (5)
C120.45889 (8)0.1345 (2)0.76784 (9)0.0286 (4)
C130.48578 (8)0.2990 (2)0.74012 (8)0.0238 (4)
C140.59529 (8)0.58574 (18)0.64612 (7)0.0188 (3)
C150.67969 (8)0.53321 (19)0.55762 (7)0.0196 (3)
C160.71756 (8)0.71403 (19)0.53550 (7)0.0198 (3)
C170.69267 (9)0.6072 (2)0.40136 (8)0.0279 (4)
C180.73319 (11)0.5676 (3)0.33926 (9)0.0366 (5)
C190.77631 (12)0.7436 (3)0.32246 (10)0.0446 (6)
C200.83604 (11)0.8219 (3)0.39494 (11)0.0431 (6)
C210.79498 (10)0.8575 (2)0.45719 (10)0.0315 (5)
O10.49086 (7)0.26239 (16)0.54011 (6)0.0284 (3)
Cl10.41634 (2)0.86809 (5)0.57854 (2)0.0257 (1)
Cl20.86696 (2)0.34916 (5)0.53733 (2)0.0275 (1)
H20.703800.616400.873700.0230*
H30.845200.590900.905800.0250*
H3A0.7923 (10)0.583 (2)0.4890 (9)0.026 (4)*
H40.911200.551000.813700.0250*
H50.839100.534600.684000.0240*
H7A0.493100.692300.719100.0240*
H7B0.558700.728800.798000.0240*
H90.533800.548200.896800.0320*
H100.489000.271600.943000.0420*
H110.443200.013500.862500.0400*
H120.439700.031100.735400.0340*
H130.485000.305200.689000.0290*
H15A0.627900.506800.519800.0230*
H15B0.715500.424400.559300.0230*
H16A0.675900.812300.519600.0240*
H16B0.759300.761800.579900.0240*
H17A0.650200.702800.383500.0330*
H17B0.667500.490500.412700.0330*
H18A0.772200.463900.355500.0440*
H18B0.692300.527000.293000.0440*
H19A0.736400.841700.299800.0540*
H19B0.805400.711300.285900.0540*
H20A0.859100.941200.383300.0520*
H20B0.880300.731000.413500.0520*
H21A0.835400.898900.503700.0380*
H21B0.754800.958900.441100.0380*
H240.5453 (10)0.591 (2)0.6091 (9)0.023 (4)*
H220.4721 (13)0.160 (3)0.5524 (12)0.048 (6)*
H230.5183 (13)0.229 (3)0.5104 (12)0.044 (6)*
Atomic displacement parameters (Å2) top
U11U22U33U12U13U23
N10.0178 (5)0.0179 (5)0.0186 (5)0.0005 (4)0.0058 (4)0.0013 (4)
N20.0176 (5)0.0189 (5)0.0165 (5)0.0002 (4)0.0042 (4)0.0005 (4)
N30.0221 (5)0.0205 (5)0.0222 (5)0.0024 (4)0.0091 (4)0.0010 (4)
C10.0179 (6)0.0144 (6)0.0198 (6)0.0005 (4)0.0048 (5)0.0008 (5)
C20.0238 (6)0.0154 (6)0.0182 (6)0.0013 (5)0.0071 (5)0.0003 (5)
C30.0240 (6)0.0154 (6)0.0190 (6)0.0016 (5)0.0015 (5)0.0002 (5)
C40.0186 (6)0.0159 (6)0.0258 (7)0.0009 (5)0.0031 (5)0.0009 (5)
C50.0201 (6)0.0172 (6)0.0225 (6)0.0012 (5)0.0076 (5)0.0000 (5)
C60.0203 (6)0.0145 (6)0.0170 (6)0.0002 (5)0.0039 (5)0.0001 (4)
C70.0184 (6)0.0210 (6)0.0234 (6)0.0016 (5)0.0089 (5)0.0001 (5)
C80.0144 (5)0.0211 (6)0.0229 (6)0.0017 (5)0.0066 (5)0.0010 (5)
C90.0267 (7)0.0305 (7)0.0241 (7)0.0058 (6)0.0095 (6)0.0023 (6)
C100.0361 (8)0.0435 (9)0.0277 (7)0.0081 (7)0.0136 (6)0.0064 (7)
C110.0273 (7)0.0288 (8)0.0439 (9)0.0042 (6)0.0123 (6)0.0095 (7)
C120.0226 (7)0.0228 (7)0.0395 (8)0.0018 (5)0.0076 (6)0.0035 (6)
C130.0222 (6)0.0249 (7)0.0241 (7)0.0012 (5)0.0063 (5)0.0017 (5)
C140.0178 (6)0.0180 (6)0.0195 (6)0.0001 (5)0.0039 (5)0.0012 (5)
C150.0222 (6)0.0201 (6)0.0167 (6)0.0004 (5)0.0062 (5)0.0019 (5)
C160.0216 (6)0.0203 (6)0.0182 (6)0.0003 (5)0.0071 (5)0.0013 (5)
C170.0300 (7)0.0353 (8)0.0180 (6)0.0018 (6)0.0066 (5)0.0020 (6)
C180.0441 (9)0.0457 (9)0.0233 (7)0.0096 (7)0.0152 (7)0.0010 (7)
C190.0551 (11)0.0507 (11)0.0389 (9)0.0161 (9)0.0306 (8)0.0128 (8)
C200.0463 (10)0.0369 (9)0.0603 (11)0.0038 (7)0.0378 (9)0.0084 (8)
C210.0345 (8)0.0222 (7)0.0448 (9)0.0006 (6)0.0227 (7)0.0038 (6)
O10.0287 (5)0.0245 (5)0.0316 (6)0.0005 (4)0.0084 (5)0.0021 (4)
Cl10.0263 (2)0.0256 (2)0.0248 (2)0.0013 (1)0.0068 (1)0.0020 (1)
Cl20.0261 (2)0.0262 (2)0.0324 (2)0.0062 (1)0.0119 (1)0.0060 (1)
Geometric parameters (Å, º) top
O1—H220.84 (2)C19—C201.519 (3)
O1—H230.85 (2)C20—C211.522 (3)
N1—C11.3947 (16)C2—H20.9300
N1—C141.3279 (16)C3—H30.9300
N1—C71.4747 (18)C4—H40.9300
N2—C141.3342 (18)C5—H50.9300
N2—C61.3973 (16)C7—H7B0.9700
N2—C151.4637 (16)C7—H7A0.9700
N3—C171.5004 (18)C9—H90.9300
N3—C161.4834 (17)C10—H100.9300
N3—C211.4974 (19)C11—H110.9300
N3—H3A0.915 (16)C12—H120.9300
C1—C21.3907 (17)C13—H130.9300
C1—C61.3925 (18)C14—H240.925 (17)
C2—C31.385 (2)C15—H15A0.9700
C3—C41.4013 (19)C15—H15B0.9700
C4—C51.3879 (19)C16—H16B0.9700
C5—C61.3928 (19)C16—H16A0.9700
C7—C81.5098 (19)C17—H17A0.9700
C8—C131.3885 (19)C17—H17B0.9700
C8—C91.3908 (19)C18—H18A0.9700
C9—C101.391 (2)C18—H18B0.9700
C10—C111.382 (2)C19—H19B0.9700
C11—C121.379 (2)C19—H19A0.9700
C12—C131.385 (2)C20—H20A0.9700
C15—C161.5243 (19)C20—H20B0.9700
C17—C181.518 (2)C21—H21B0.9700
C18—C191.508 (3)C21—H21A0.9700
Cl1···C143.5484 (14)C15···H17B2.6100
Cl1···O1i3.1722 (12)C17···H13i3.0700
Cl1···O1ii3.1919 (12)C17···H15A2.7900
Cl2···N33.0066 (13)C17···H15B3.0700
Cl2···C163.6010 (14)C19···H18Bix3.0500
Cl2···C9iii3.6243 (15)H2···C73.0000
Cl2···C153.5749 (15)H2···H7B2.5900
Cl1···H21Biv3.0900H2···Cl2vii2.8100
Cl1···H23i2.33 (2)H3···H23vii2.5800
Cl1···H3v3.0500H3···Cl1x3.0500
Cl1···H7A2.8000H3···H16Aiii2.4600
Cl1···H12ii3.0000H3A···H15B2.3600
Cl1···H15Ai3.1300H3A···H20B2.5400
Cl1···H242.864 (16)H3A···H18A2.5000
Cl1···H17Bi2.9100H3A···Cl22.100 (15)
Cl1···H22ii2.35 (2)H4···H13vii2.5200
Cl1···H16Aiv3.0000H4···C12vii3.0700
Cl2···H53.1300H4···C13vii2.8400
Cl2···H15B2.7900H5···C153.0200
Cl2···H2iii2.8100H5···Cl23.1300
Cl2···H7Biii3.0200H5···H16B2.5400
Cl2···H3A2.100 (15)H7A···H12ii2.5800
Cl2···H9iii2.7500H7A···Cl12.8000
O1···C143.1626 (17)H7A···H242.5300
O1···Cl1i3.1722 (12)H7B···H22.5900
O1···C15i3.2734 (18)H7B···H92.3400
O1···Cl1vi3.1919 (12)H7B···C22.9600
O1···H132.7700H7B···Cl2vii3.0200
O1···H24i2.805 (16)H9···H7B2.3400
O1···H16Ai2.8000H9···Cl2vii2.7500
O1···H15Ai2.5700H11···H20Bxi2.3500
O1···H242.648 (15)H12···Cl1vi3.0000
N1···N22.1864 (15)H12···H7Avi2.5800
N1···C4vii3.2982 (17)H13···H4iii2.5200
N2···C3iii3.3364 (17)H13···C142.9800
N2···N12.1864 (15)H13···N12.8600
N3···Cl23.0066 (13)H13···O12.7700
N1···H132.8600H13···C17i3.0700
C1···C5vii3.2347 (17)H13···H17Ai2.3100
C1···C4vii3.4640 (18)H15A···C172.7900
C1···C6vii3.5960 (17)H15A···H17B2.2500
C2···C16iii3.5013 (18)H15A···O1i2.5700
C2···C6vii3.4336 (18)H15A···H242.5200
C2···C5vii3.3221 (18)H15A···Cl1i3.1300
C3···N2vii3.3364 (17)H15B···C3iii2.9700
C3···C6vii3.5129 (18)H15B···Cl22.7900
C3···C16iii3.4099 (18)H15B···C173.0700
C3···C15vii3.4983 (18)H15B···H3A2.3600
C4···C13vii3.446 (2)H15B···C2iii2.9300
C4···C14iii3.4895 (18)H15B···C53.0700
C4···C1iii3.4640 (18)H16A···H17A2.5100
C4···N1iii3.2982 (17)H16A···C3vii2.9500
C5···C163.4994 (18)H16A···H3vii2.4600
C5···C2iii3.3221 (18)H16A···H21B2.4600
C5···C1iii3.2347 (17)H16A···Cl1iv3.0000
C6···C3iii3.5129 (18)H16A···O1i2.8000
C6···C2iii3.4336 (18)H16A···H22i2.5000
C6···C1iii3.5960 (17)H16B···C52.8800
C9···Cl2vii3.6243 (15)H16B···C62.8200
C13···C17i3.442 (2)H16B···C2vii2.7800
C13···C143.513 (2)H16B···H21A2.3700
C13···C4iii3.446 (2)H16B···C3vii2.9900
C14···Cl13.5484 (14)H16B···H52.5400
C14···O13.1626 (17)H17A···H13i2.3100
C14···C4vii3.4895 (18)H17A···C12i3.0700
C14···C133.513 (2)H17A···C13i2.7300
C15···Cl23.5749 (15)H17A···H21B2.5300
C15···C3iii3.4983 (18)H17A···H16A2.5100
C15···O1i3.2734 (18)H17B···C152.6100
C16···C53.4994 (18)H17B···H15A2.2500
C16···C3vii3.4099 (18)H17B···Cl1i2.9100
C16···C2vii3.5013 (18)H18A···H3A2.5000
C16···Cl23.6010 (14)H18B···C19xii3.0500
C17···C13i3.442 (2)H20A···C9xiii2.9100
C2···H16Biii2.7800H20A···C10xiii2.9200
C2···H15Bvii2.9300H20B···H3A2.5400
C2···H7B2.9600H20B···H11xiv2.3500
C3···H16Biii2.9900H21A···C9vii2.9800
C3···H15Bvii2.9700H21A···H16B2.3700
C3···H16Aiii2.9500H21B···H17A2.5300
C5···H16B2.8800H21B···Cl1iv3.0900
C5···H15B3.0700H21B···H16A2.4600
C6···H16B2.8200H22···H16Ai2.5000
C7···H23.0000H22···Cl1vi2.35 (2)
C9···H20Aviii2.9100H23···H24i2.48 (3)
C9···H21Aiii2.9800H23···Cl1i2.33 (2)
C10···H20Aviii2.9200H23···H3iii2.5800
C12···H4iii3.0700H24···H23i2.48 (3)
C12···H17Ai3.0700H24···Cl12.864 (16)
C13···H4iii2.8400H24···O12.648 (15)
C13···H17Ai2.7300H24···H7A2.5300
C14···H132.9800H24···H15A2.5200
C15···H53.0200H24···O1i2.805 (16)
H22—O1—H23105 (2)N1—C7—H7A109.00
C1—N1—C7125.86 (11)H7A—C7—H7B108.00
C1—N1—C14108.36 (11)C8—C7—H7B109.00
C7—N1—C14125.76 (11)C8—C9—H9120.00
C6—N2—C14108.17 (10)C10—C9—H9120.00
C6—N2—C15126.09 (11)C11—C10—H10120.00
C14—N2—C15125.74 (11)C9—C10—H10120.00
C16—N3—C21109.32 (11)C10—C11—H11120.00
C17—N3—C21111.10 (11)C12—C11—H11120.00
C16—N3—C17112.11 (11)C13—C12—H12120.00
C21—N3—H3A109.8 (10)C11—C12—H12120.00
C16—N3—H3A107.0 (10)C8—C13—H13120.00
C17—N3—H3A107.4 (10)C12—C13—H13120.00
N1—C1—C2131.10 (12)N2—C14—H24125.4 (11)
C2—C1—C6122.26 (12)N1—C14—H24124.1 (11)
N1—C1—C6106.61 (10)N2—C15—H15A110.00
C1—C2—C3115.79 (12)C16—C15—H15A110.00
C2—C3—C4122.19 (12)C16—C15—H15B110.00
C3—C4—C5121.91 (13)N2—C15—H15B110.00
C4—C5—C6115.88 (12)H15A—C15—H15B108.00
N2—C6—C1106.42 (11)N3—C16—H16B109.00
C1—C6—C5121.97 (11)C15—C16—H16A109.00
N2—C6—C5131.60 (11)C15—C16—H16B109.00
N1—C7—C8112.37 (11)H16A—C16—H16B108.00
C7—C8—C9120.21 (12)N3—C16—H16A109.00
C7—C8—C13120.33 (11)N3—C17—H17B110.00
C9—C8—C13119.42 (12)C18—C17—H17A110.00
C8—C9—C10119.83 (13)N3—C17—H17A110.00
C9—C10—C11120.09 (14)H17A—C17—H17B108.00
C10—C11—C12120.31 (14)C18—C17—H17B110.00
C11—C12—C13119.80 (13)C17—C18—H18A109.00
C8—C13—C12120.55 (13)C17—C18—H18B109.00
N1—C14—N2110.43 (11)C19—C18—H18B109.00
N2—C15—C16109.17 (10)H18A—C18—H18B108.00
N3—C16—C15112.05 (11)C19—C18—H18A109.00
N3—C17—C18110.35 (13)C18—C19—H19B109.00
C17—C18—C19111.26 (15)C20—C19—H19A109.00
C18—C19—C20111.11 (15)C20—C19—H19B109.00
C19—C20—C21111.62 (16)H19A—C19—H19B108.00
N3—C21—C20110.29 (13)C18—C19—H19A109.00
C3—C2—H2122.00C19—C20—H20B109.00
C1—C2—H2122.00C21—C20—H20A109.00
C2—C3—H3119.00C19—C20—H20A109.00
C4—C3—H3119.00H20A—C20—H20B108.00
C5—C4—H4119.00C21—C20—H20B109.00
C3—C4—H4119.00N3—C21—H21A110.00
C4—C5—H5122.00N3—C21—H21B110.00
C6—C5—H5122.00C20—C21—H21B110.00
N1—C7—H7B109.00H21A—C21—H21B108.00
C8—C7—H7A109.00C20—C21—H21A110.00
C7—N1—C1—C20.3 (2)C2—C1—C6—C50.22 (19)
C14—N1—C1—C2178.95 (13)C2—C1—C6—N2179.33 (11)
C7—N1—C1—C6177.80 (11)N1—C1—C6—C5178.07 (11)
C14—N1—C1—C60.87 (14)N1—C1—C2—C3177.97 (12)
C1—N1—C7—C881.97 (15)C1—C2—C3—C40.25 (18)
C14—N1—C7—C899.59 (14)C2—C3—C4—C50.0 (2)
C1—N1—C14—N20.34 (14)C3—C4—C5—C60.36 (18)
C7—N1—C14—N2178.33 (11)C4—C5—C6—C10.47 (18)
C14—N2—C6—C10.86 (14)C4—C5—C6—N2179.33 (13)
C14—N2—C15—C16108.14 (14)N1—C7—C8—C9124.84 (14)
C15—N2—C14—N1178.64 (11)N1—C7—C8—C1357.66 (16)
C15—N2—C6—C52.9 (2)C13—C8—C9—C100.1 (2)
C6—N2—C15—C1673.07 (16)C7—C8—C13—C12177.40 (13)
C6—N2—C14—N10.33 (15)C7—C8—C9—C10177.63 (14)
C15—N2—C6—C1178.11 (11)C9—C8—C13—C120.1 (2)
C14—N2—C6—C5178.13 (13)C8—C9—C10—C110.1 (3)
C17—N3—C16—C1559.98 (14)C9—C10—C11—C120.5 (3)
C17—N3—C21—C2057.97 (17)C10—C11—C12—C130.8 (2)
C21—N3—C16—C15176.38 (11)C11—C12—C13—C80.6 (2)
C16—N3—C17—C18178.61 (12)N2—C15—C16—N3163.04 (10)
C21—N3—C17—C1858.75 (16)N3—C17—C18—C1956.70 (17)
C16—N3—C21—C20177.79 (13)C17—C18—C19—C2054.3 (2)
N1—C1—C6—N21.04 (13)C18—C19—C20—C2153.7 (2)
C6—C1—C2—C30.15 (18)C19—C20—C21—N355.3 (2)
Symmetry codes: (i) x+1, y+1, z+1; (ii) x, y+1, z; (iii) x+3/2, y1/2, z+3/2; (iv) x+1, y+2, z+1; (v) x1/2, y+3/2, z1/2; (vi) x, y1, z; (vii) x+3/2, y+1/2, z+3/2; (viii) x1/2, y+3/2, z+1/2; (ix) x+3/2, y+1/2, z+1/2; (x) x+1/2, y+3/2, z+1/2; (xi) x1/2, y+1/2, z+1/2; (xii) x+3/2, y1/2, z+1/2; (xiii) x+1/2, y+3/2, z1/2; (xiv) x+1/2, y+1/2, z1/2.
Hydrogen-bond geometry (Å, º) top
D—H···AD—HH···AD···AD—H···A
N3—H3A···Cl20.915 (16)2.100 (15)3.0066 (13)170.5 (15)
O1—H22···Cl1vi0.84 (2)2.35 (2)3.1919 (12)176 (2)
O1—H23···Cl1i0.85 (2)2.33 (2)3.1722 (12)175 (2)
C2—H2···Cl2vii0.932.813.6549 (14)152
C7—H7A···Cl10.972.803.6930 (15)153
C9—H9···Cl2vii0.932.753.6243 (15)158
C15—H15A···O1i0.972.573.2734 (18)129
C15—H15B···Cl20.972.793.5749 (15)139
Symmetry codes: (i) x+1, y+1, z+1; (vi) x, y1, z; (vii) x+3/2, y+1/2, z+3/2.
 

Follow Acta Cryst. E
Sign up for e-alerts
Follow Acta Cryst. on Twitter
Follow us on facebook
Sign up for RSS feeds