Download citation
Download citation
link to html
The Advanced Photon Source (APS) now has a total of 23 insertion devices (IDs). Over two-thirds of them are installed on the storage ring. The installed devices include 18, 27 and 55 mm-period undulators; an 85 mm-period wiggler; a 16 cm-period elliptical multipole wiggler; and many 33 mm-period undulators. Most of the IDs occupy storage-ring straight sections equipped with 8 mm vertical-aperture vacuum chambers. All of the IDs were measured magnetically at the APS and, in most cases, underwent a final magnetic tuning in order to minimize variation in the various integrals of the field through the ID over the full gap range. Special shimming techniques to correct magnetic field parameters in appropriate gap-dependent ways were developed and applied. Measurements of the closed-orbit distortion as a function of the ID gap variation have been completed, and results are in a good agreement with magnetic measurements. Spectral diagnostics of the ID radiation, including measurements of the absolute spectral flux, brilliance and polarization, show excellent agreement between calculated and measured results. Studies of the sensitivity of IDs to radiation exposure and measurements of the dose rate received by the IDs are in progress.