research papers
A brief review of methods of measuring birefringence is given. Apparatus for the accurate measurement of optical birefringence at high temperatures using a modulation (rotating-analyser) method is described in detail, together with suggestions for further applications of the equipment. The technique is applied to the particular case of the ferroelastic monoclinic-tetragonal phase transition in BiVO4. The birefringence was found to show mean-field behaviour over a wide temperature range with a mean-field transition temperature of 519.9 (3) K.